A Review of the Proposed K (sub Isi) Offset-Secant Method for Size-Independent Linear-Elastic Toughness Evaluation

Abstract: The proposed size-independent linear-elastic fracture toughness, K (sub Isi), for potential inclusion in ASTM E399 targets a consistent 0.5 millimeters crack extension for all specimen sizes through an offset secant that is a function of the specimen ligament length. The K (sub Isi) method also includes an increase in allowable deformation, and the removal of the P (sub max)/P (sub Q) criterion. A finite element study of the K (sub Isi) test method confirms the viability of the increased defo…